Description
SFM series flow meter is a device that has been designed to intercept and measure the amount of fluid flowing through a pipe by the interaction of an impeller immersed in the fluid and a Hall probe.
Technical Data
| Mounting position | Horizontal, vertical |
| Operating pressure range | ≤ 10 bar |
| Connection | RAST 2.5 |
| Sensor type | Hall effect |
| Power supply | 3 ... 24 Vdc |
| Current load | 25 mA max. |
| Output signal | Frequency duty cycle 50% |
| Flow rates | 1 ... 15 l/m |
| Ambient temperature | +2 °C ... 60°C |
| Water temperature | +2 °C ... 70°C |
| Inlet/Outlet | See drawings |
| Degree of protection | IP 00 |
Coding
Connection
hydraulic
Features
functional
SFMAU10Z00
(4 poles)
Features
functional
SFMAU10Z10
(2 poles)
Coding

Connection
hydraulic

Features
functional
SFMAU10Z00
(4 poles)
SFMAU10Z00



Features
functional
SFMAU10Z10
(2 poles)
SFMAU10Z10



Electrical connection

Electrical diagram

- The value of 10 kΩ is for reference only and can be sized according to the supply voltage while respecting the current limit (see the “technical data” section).
Electrical connection

Electrical diagram