PRESSURE SWITCH – SL SERIES
Description
Compact device used in heating system boiler to check minimum water pressure.
Max static pressure | 6 bar |
Fixing working pressure | 0.5 bar (optional 0.4 / 0.3 bar) FALLING |
Histeresis | 0,1 ÷ 0,4 bar |
Ambient temperature | -20°C ÷ 60°C |
Water temperature | < 90° |
Voltage | 5Vdc/24Vdc - 230Vac (16A) |
Connection terminal | 6.3 x 0.8 mm, RAST 5 or RAST 2.5 |
Hydraulic inlet (PLASTIC) | See connection pag. 6-7 catalogue |
Grado di protezione / Protection Class | IP00 |
Peso / Weight | ∼ 22 grammi / grams |
Approval
- EN60730-1, EN60730-2-6, EN60335-1-2002
- All our products conform to the 2002/95/EC European directive (RoHS).
Storage
- Avoid the transducer coming into contact with powders
- Do not store in locations with humidity condensation
- Storage temperature: ∼ 25°C
Code scheme